+ What is an electronic voltage stabilizer?

Voltage Stabilizers, as the name suggests, help stabilize the voltage. This means, if the supply voltage fluctuates or varies, it automatically brings it to the desired range.

It does so by using a combined mechanism of an auto transformer and electro-mechanical relays.

+ Does a stabilizer give constant voltage output?

No. But it helps operate the connected appliance/equipment in a safe voltage range.

+ How does one select the right stabilizer for their equipment?

A simple way to select the right stabilize

  • Check the Voltage & current rating of the device. It is written on the sticker near power socket else check the manual
  • In India typically the voltage will be 220V
  • Multiply 220 x Current of all devices and then add the individual device's VAs. Add a 20-25% safety margin to arrive at stabilizer rating. If you have plans to add more devices later, you can keep buffer for them
  • You should also consider the surge current which flows when you switch on the device

+ How does the stabilizer protect the connected equipment?

The stabilizer will give a stabilized and safe voltage to the connected equipment within the specified limit even if the input voltage is high or low. It does so by using an auto transformer having a number of tapings, which will be selected as primary/ secondary for step up/ step down operations in accordance with the input voltage level. The tapping selection is done by using appropriate arrangement of relays.

+ What is the importance of Time Delay?

Time Delay system helps the compressor to get proper balancing time during power cuts. It will protect the compressor from frequent re-starting and ensures the safety of the connected equipment, in case of Voltage fluctuation by providing a delay.

+ What is the duration of normal Time Delay?

Usually, the duration of Time Delay is between 2 to 4 minutes.

+ What is ITDS?

ITDS means Intelligent Time Delay System. This feature provides a Time Delay only when it is actually necessary, which means there is no initial Time Delay.

+ How does the Time Delay increase the life of the compressor?

Time Delay gives the compressor balancing time between power cuts thereby enhancing its life.

+ Why are the Low voltage cut-off and High voltage cut-off necessary?

All electrical and electronic items are sensitive to high voltage. If the input voltage of the connected equipment is more than 270 V, it harms the equipment. For some electronic equipment, even if the input voltage reaches above 250 Volt, there may be some malfunctioning. To protect the equipment, it makes it necessary to have these cut-offs.

+ Can TV stabilizers be used for refrigerators?

No, because the working range requirement for refrigerators and TV are different. Refrigerators require stabilizers withlow voltage cut-off and time delay other than the high voltage cut off. However, the TV stabilizers are only equipped with a high voltage cut-off.

+ Can a refrigerator stabilizer be kept on top of the refrigerator?

It is always advisable to keep it on a separate stand.

+ Is a volt meter necessary for a stabilizer?

No, it’s not necessary. Since stabilizers already have the low cut-off and high cut-off feature, they will automatically turn off the connected equipment during voltage fluctuations.

+ What is meant by Spike?

Spike is a kind of line noise voltage or it can be termed as the abrupt raise in the voltage which lasts for a very short period of time. Such a dangerous voltage(upto Kilovolt range) can damage sensitive electronic equipment.

+ What is ZCD technology?

ZCD or Zero Crossing Detection Technology helps enhance the stabilizer’s life and reduce the radio frequency noise generation. The Relay changeover in the stabilizer takes place during the Zero Crossing period of the AC Mains input voltage.

+ Can we use normal TV stabilizer for LCD TV?

It is advisable to use specially designed V-Guard LCD TV Stabilizer to protect and enhance the performance of your LCD TV. Compared to CRT TVs, the LCD / LED TVs are moresensitive to voltage fluctuations and spikes. The working ranges of LCD / LED TVs are from 90V to 290V. It shows that these TVs are more sensitive to high voltages.

+ Is it necessary to use a stabilizer even if my refrigerator is stabilizer free?

Yes, no matter what the model, a stabilizer is required. There is no stabilizer inside the refrigerator. Refrigerator companies claim that it can work at both, low and high voltage. But operating the refrigerator at a low voltage affects its cooling efficiency and its life. Also, there is no low voltage cut-off & high voltage cut-off in the refrigerator. This is the reason major refrigerator companies insist on using a good quality voltage stabilizer, in their warranty card.

V-GUARD offers a range of products from Voltage Stabilizer to Digital UPS, Inverter and Inverter Batteries, Electric Water Heaters, Solar Water Heaters, Domestic Pumps, Agricultural Pumps, Industrial Motors, Domestic Switch Gears, Distribution Boards, Wiring Cables, Industrial Cables, Induction Cooktops, Mixer Grinders, Fans, Rice Cooker, Gas Stoves, Solar Power Systems & Air Coolers.

Contact Us

Products
  • Voltage Stabilizers
  • Fans
  • Kitchen Appliances
  • Solar Power System
  • Pumps
  • Domestic Switch Gears
  • Modular Switches
  • Air Coolers
  • Water Purifier
  • Product Brochures
Company
  • ABOUT V-GUARD
  • BRAND PHILOSOPHY
  • BROWSE PRODUCTS
  • Buy Products Online
  • FAQs
  • FIND A DEALER
  • CUSTOMER CARE
  • MEDIA CENTER
  • V-GUARD GSTIN
  • Company Policies
  • BIG IDEA B-PLAN CONTEST
  • BIG IDEA TECH DESIGN CONTEST
INVESTOR RELATIONS
  • CORPORATE GOVERNANCE REPORT
  • ANNUAL REPORTS
  • PROSPECTUS
  • CODE OF CONDUCT
V-GUARD UNIVERSE
V-Guard Customer Support |FAQs (2024)

FAQs

What does the code oH1 mean on a V-Guard stabilizer? ›

oH1 - Overheat Fault. An oH1 (Overheat Fault) will occur when the heatsink temperature reaches the overheat fault level (typically 5° C to 10° C above L8-02).

Why is my AC stabilizer showing a red light? ›

The display of the STAB range of products comes with two LEDS of the front panel. Green to mean voltage good and a red to mean input supply voltage is not good. Both red and green LEDs remain on- indicates input supply is either too high or too low and the unit is rectifying it.

Why is my V-Guard stabilizer showing hi? ›

That uncle said that if the indication provided in the stabilizer shows “H”, it means that the incoming Voltage is High and beyond the range of the stabilizer. Generally stabilizers have a moving switch to check the Input Voltage so you can check whether it is normal or High.

Why is my stabilizer not working? ›

The first step is to check the circuit breaker or fuse. If the circuit breaker or fuse has tripped, reset it and see if the stabilizer begins to work properly. If this doesn't resolve the issue, you may need to check the wiring. Make sure all the connections are secure and that there are no loose or frayed wires.

What does Lo mean on stabilizer? ›

Lo refers to the low incoming voltage in the stabilizer. Explanation: Lo is the error code in the power systems. In a stabilizer, Lo is shown where there is low incoming voltage than a threshold voltage. Every stabilizer has a threshold value of voltage.

What is the error code H1 on V Guard stabilizer? ›

You get the H1 error code when the stabilizer's output is too high. The reasons will vary. Sometimes, the domestic mains line is the problem. If the input supply voltage is too high, you can normally blame it on a malfunction in the grid.

What is the red light on the V guard stabilizer input? ›

IN A V GUARD VOLTAGE STABILISER, THE FIRST RED LIGHT WILL GLOW WHEN YOU SWITCH ON THE STABILISER. AFTER ABOUT A MINUTE, THE SECOND RED LIGHT WILL ALSO GLOW AND THE SUPPLY WILL BE CONNECTED TO THE AC. IF IT IS NOT WORKING, THEN, PROBABLY, THE CONTACTOR IS MALFUNCTIONING.

Why is the green light not working on my V Guard stabilizer? ›

The green light and yellow light on the stabiliser shows line voltage. The light is sometimes not visible when the line voltage is too high ( over voltage) or too low. Check also your line voltage. This cut off is implemented in the stabilisers as a protection to your equipment.

How do I fix the red light on my air conditioner? ›

Air Filter Needs Cleaning - In some units, the red, flashing light may simply indicate a dirty air filter. This can be easily remedied at home by cleaning the air filter and evaporator coils. Use soapy water to clean the filter, and vacuum the evaporator coil while the aircon is shut off and unplugged.

What is the click sound on the V guard stabilizer? ›

When the carbon brush is moving, there is a noticeable "click" noise or fire between the coils. This is caused by the poor contact between the carbon brush and the coil.

What happens if you overload a stabilizer? ›

25kva stabilizer will get heated up slkwly and then if kept on will make itd winding burnt out.. Overload means loading more than rated load. Immediate effect of overload is drop of output voltage. Consistant overload will blow fuse to protect transformer winding.

Why is my stabilizer showing red light? ›

If the voltage is not more than 170 Volts, then it gave the red indication and does not work. 4. The stabilizer is equipped with auto cut-off if the voltage is outside 170-270 volts voltage range, then it won't work.

How do you fix a stuck stabilizer? ›

Sticky/slow stabilizers troubleshooting
  1. Reseat the keycap. ...
  2. Check the interaction between the stab wire and the plate. ...
  3. Is the stab wire perfectly straight along its length?
  4. Are the stab housings properly mounted on the PCB or plate?
Dec 24, 2021

Why is my AC not switching on even after the stabilizer is on? ›

Faulty wiring and loose connections can also be the reason why you uncover your air conditioning not turning on. Additionally, these wiring issues can lead to several other problems with an AC unit. Broken wires can cause electrical problems including tripped breakers and fire hazards.

What is the code for voltage stabilizer? ›

85044040

Top Articles
Latest Posts
Article information

Author: Fredrick Kertzmann

Last Updated:

Views: 5759

Rating: 4.6 / 5 (66 voted)

Reviews: 89% of readers found this page helpful

Author information

Name: Fredrick Kertzmann

Birthday: 2000-04-29

Address: Apt. 203 613 Huels Gateway, Ralphtown, LA 40204

Phone: +2135150832870

Job: Regional Design Producer

Hobby: Nordic skating, Lacemaking, Mountain biking, Rowing, Gardening, Water sports, role-playing games

Introduction: My name is Fredrick Kertzmann, I am a gleaming, encouraging, inexpensive, thankful, tender, quaint, precious person who loves writing and wants to share my knowledge and understanding with you.