"Run time” refers to the amount of time aUPSwill provide power once the main utility power is interrupted. Standard battery run time for a commonUPSis around 5 to 10 minutes under full load and about twice that under half load. (Run times are often quoted as minutes under full and half load.)

The battery run time during a power outage is a function of the current load placed on the battery and the size of the battery. The demand for current by the equipment being powered is expressed in "amps”. The amount of "juice” stored in a battery is expressed in terms of "amp-hours”. (One amp-hour is a current flow of one amp for one hour.) If you want to know how long a given set of equipment will operate off aUPSbattery, add up the current in amps that the equipment will pull and divide the amp hours of theUPSby that number. (e.g. A ½ amp load on a 2 amp-hour battery will run for 4 hours.)

So, it makes sense that the smaller the load relative to the size of the battery the longer the run time. Over-sizing aUPSrelative to the load is one way to get extended run time. SomeUPSmodels allow special external battery packs to be connected to theUPSto extend run times. Check with your supplier or the product specifications.

A battery will not provide full voltage through its entire rated amp-hour life. Some reduction in voltage will occur at the end of the functional operation of the battery, just as a flashlight becomes dim but still works. Some UPSs will provide automatic shutdown or alarm when this voltage decline is imminent. So, if you have a specific required battery run time in case of a power outage, it’s best to have a bit of amp-hour head room on top of what you calculate.

"Middle market” and top of the line UPSs have replaceable batteries. Since even continually charged batteries have a limited service life of three to five years, being able to replace them is a nice feature.UPSbatteries pose no danger with normal operation. But, they should be disposed of properly.

Recent advances in battery technology provide choices in battery designs for various applications and price points.Lead acidbatteries are heavy and are the most common type used. A 600 wattUPSweighs around 30 pounds. A 2200 watt unit weighs around 80 pounds.

Simple and sophisticated UPSs alike have warning indicators for loss of main utility power and for low battery power. A warning will also indicate when the battery is reaching the end of its useful life and needs to be replaced. In someUPSmodels the battery status can be remotely monitored over RS232 or Ethernet communication links.

Battery Run Time - AC Power Distribtion, Conditioning, and Control at JuiceGoose (2024)
Top Articles
Latest Posts
Article information

Author: Maia Crooks Jr

Last Updated:

Views: 6539

Rating: 4.2 / 5 (63 voted)

Reviews: 94% of readers found this page helpful

Author information

Name: Maia Crooks Jr

Birthday: 1997-09-21

Address: 93119 Joseph Street, Peggyfurt, NC 11582

Phone: +2983088926881

Job: Principal Design Liaison

Hobby: Web surfing, Skiing, role-playing games, Sketching, Polo, Sewing, Genealogy

Introduction: My name is Maia Crooks Jr, I am a homely, joyous, shiny, successful, hilarious, thoughtful, joyous person who loves writing and wants to share my knowledge and understanding with you.